C&I ESS 100kW 120kW 125kW 215kWh 233kWh 241kWh 261kWh Liquid Cooling Energy Storage System


High Capacity: 215kWh to 261kWh energy storage using LiFePO4 batteries
Powerful Output: 100kW120kW 125kW rated power
Advanced Safety: Built in liquid cooling system, Integrated fire suppression and comprehensive electrical protection
Smart Connectivity: Supports RS485, Modbus TCP for seamless integration and monitoring
Durable Design: IP54 rated enclosure for demanding environments
Flexible Installation: Suitable for indoor applications
Reliable Operation: Designed for long-lasting performance and stability

Product Features
Three phase 100%unbalanced load
Three phase 100%unbalanced load
Three phase 100%unbalanced load
Three phase 100%unbalanced load
Three phase 100%unbalanced load
Three phase 100%unbalanced load
Related Data
ModuleVN-100K-LCH215VN-100K-LCH233VN-120K-LCH241VN-125K-LCH261
Battery
Battery TypeLiFePO₄
Rated Charge/Discharge Performance0.5C
Nomnal Voltage768V832V768V832V
Operating Voltage Range672-876V728-949V672-876V728-949V
Cell Rated Capacity280Ah280Ah314Ah314Ah
Rate Capacity215.04kWh232.96kWh241.15kWh261.248kWh
Composition1P240S1P260S1P240S1P260S
AC Output(Grid Side)
Rated Output Power100kW100kW120kW125kW
Max.Output Current159A159A191A198A
Rated Grid Voltage3/N/PE, 230/400V3/N/PE, 230/400V3/N/PE,400V3/N/PE,230/400
Rated Grid Frequency50/60Hz
Power Factor>0.99
Adjustable Power Factor Range0.9 leading ~ 0.9 lagging
DC Component<0.5% In
Total Voltage Waveform Distortion Rate<3% (@ rated power)
AC Output(Load Side)
Rated Output Power100kW100kW120kW125kW
Max.Output Current159A159A191A198A
Rated Output Voltage3/N/PE, 230/400V
Rated Output Frequency50/60Hz
Unblanced Load Capacity100%
General Date
Ingress ProtectionIP54
Cooling MethodBattery compartment (Liquid cooling), Electrical compartment (Air cooling)
Fire Protection SystemAerosol, Perfluorohexanone
Relative Humidity0~95%, no condensation
Operating Temperature-20~+50℃
Altitude4000m (>2000m requires derating)
Communication MethodRS485、CAN
Communication ProtocolModbus、IEC104
Reference weight2600kg2800kg2350kg2800kg
Reference size1000*1330*2350mm1000*1400*2400mm1000*1330*2350mm1000*1400*2400mm
Transportation MethodOverall transportation

Lorem ipsum dolor sit amet

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.

FAQ

By default, this panel is concealed and appears when the user clicks on the section title. Input relevant information about its title using paragraphs or bullet points. Accordions can enhance the user experience when utilized effectively. They allow users to choose what they want to read and disregard the rest. Accordions are often utilized for frequently asked questions (FAQs).

By default, this panel is concealed and appears when the user clicks on the section title. Input relevant information about its title using paragraphs or bullet points. Accordions can enhance the user experience when utilized effectively. They allow users to choose what they want to read and disregard the rest. Accordions are often utilized for frequently asked questions (FAQs).

By default, this panel is concealed and appears when the user clicks on the section title. Input relevant information about its title using paragraphs or bullet points. Accordions can enhance the user experience when utilized effectively. They allow users to choose what they want to read and disregard the rest. Accordions are often utilized for frequently asked questions (FAQs).

By default, this panel is concealed and appears when the user clicks on the section title. Input relevant information about its title using paragraphs or bullet points. Accordions can enhance the user experience when utilized effectively. They allow users to choose what they want to read and disregard the rest. Accordions are often utilized for frequently asked questions (FAQs).

Tags:

  • All in one C&I Energy Storgae System